A famous example of concurrent engineering is the development of the Boeing 777 commercial aircraft. The aircraft was designed and built by geographically distributed companies that worked entirely on a common product database of C A TIA without building physical mock-ups but with digital product definitions.
A two-position mode controller is used to control the water level in a tank by opening or closing a valve which in the open position allows water at the rate of 0.4 m3 / s to enter the tank. The tank has a cross-sectional area of 12 m2 and water leaves it at the constant rate of 0.2 m3 / s. The valve opens when the water level reaches 4.0 m and closes at 4.4 m. What will be the times taken for (a) the valve opening to closing, (b) the valve closing to opening
Answer:
The right solution is:
(a) 24 sec
(b) 24 sec
Explanation:
The given values are:
Water inlet's flow rate,
= 0.4 m³/s
Water outlet's flow rate,
= 0.2 m³/s
(a)
The volume of water filled will be:
= [tex]Area(height)[/tex]
= [tex]12(4.4-4)[/tex]
= [tex]12\times 0.4[/tex]
= [tex]4.8 \ m^3[/tex]
Opening to closing time taken will be:
= [tex]\frac{4.8}{0.2}[/tex]
= [tex]24 \ sec[/tex]
(b)
Inlet's flow rate,
= 0
Outlet's flow rate will be:
= 0.2 m³/s
Closing to opening time taken will be:
= [tex]\frac{4.8}{0.2}[/tex]
= [tex]24 \ sec[/tex]
a. The time taken for the valve opening to closing is 24 seconds.
b. The time taken for the valve closing to opening is 24 seconds.
Calculation of the time taken:a.
First we need to determine the volume of the water
= Area * height
= 12*(4.4-4)
= 12*0.4
= 4.8
Now the time taken should be
= 4.8/0.2
= 24 seconds.
b. The time taken should be
= 4.8/0.2
= 2.4 seconds
Learn more about time here: https://brainly.com/question/24331923
ogla has mistakenly created a connection between the black and white wire. What has she created? A) open circuit B) SHORT CIRCUIT C) GROUND CIRCUIT D) AC
Answer:
B) SHORT CIRCUIT
Explanation:
a poorly tighten terminal is often the cause of a/an ? a) open circuit b) circuit breaker interrupt c)short circuit d) ground fault
Answer: b) circuit breaker interrupt
Explanation:
Wires connect to outlets through terminals and these terminals need to be tight to ensure that electricity flows with the minimum amount of resistance.
If the terminal is poorly tightened, what happens is that resistance will build up as the appliance is being used and this resistance will make the terminal hotter.
The heat will continue to rise until the circuit breaker trips to interrupt the circuit and protect the appliance.